EasyManua.ls Logo

Sharp PN-LA862 - Page 9

Sharp PN-LA862
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
CONTROL FUNCTION COMMAND
(HTTP SERVER)
CFHS
WR
0~1
0~1
0: OFF, 1: ON
●
POWER MANAGEMENT
PMNG
WR
0~1
0~1
0: OFF, 1: ON
POWER SAVE MODE
STBM
WR
0~1
0~1
0: OFF, 1: ON
QUICK START
QUST
WR
0~1
0~1
0: OFF, 1: ON
●
*2
POWER ON DELAY
PODS
WR
0~1
0~1
0: OFF, 1: ON
●
INTERVAL of POWER ON DELAY
PWOD
WR
1~60
1~60
INTERVAL of POWER ON DELAY (second)
ADJUSTMENT LOCK
ALCK
WR
0~2
0~2
0: OFF, 1: ON1, 2: ON2
ADJUSTMENT LOCK TARGET
ALTG
WR
0~2
0~2
0: REMOTE CONTROL, 1: MONITOR BUTTON, 2: BOTH
TEMPERATURE ALERT
TALT
WR
0~2
0~2
0: OFF, 1: OSD & LED, 2: LED
STATUS ALERT
SALT
WR
0~2
0~2
0: OFF, 1: OSD & LED, 2: LED
USB PORT FOR SERVICE
UPFS
WR
0~1
0~1
0: OFF, 1: ON
SIGNAL RESPONSE LEVEL
HDUC
WR
1~200
1~200
MULTIPLE DISPLAY MODE
MPDM
WR
0~1
0~1
0: OFF, 1: ON
OPTION SLOT
POWER CONTROL
CPOW
WR
0
0
POWER OFF
△
WR
1
1
POWER ON
W
5555
FORCE POWER OFF
W
9999
RESET
AUTO SHUTDOWN
CCOP
WR
0~1
0~1
0: OFF, 1: ON
●
AUTO DISPLAY OFF
OPAD
WR
0~1
0~1
0: OFF, 1: ON
SIGNAL SELECT
OASS
WR
0~2
0~2
0: AUTO, 1: DisplayPort, 2: TMDS
INTERFACE
CAPABILITY
OAIC
R
0~3
0~3
0: NONE, 1: DisplayPort, 2: TMDS, 3: DisplayPort, TMDS
Model
INF1
R
Model name
Serial no.
SRNO
R
Serial no
*2 This command can’t use when “POWER SAVE MODE” is “ON”
Function menu
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
All Reset
RSET
W
0~1
0: All reset 1, 1: All reset 2
―
Others
Function
Command
Direction
Parameter
Reply
Control/Response contents
*
SIZE
WIDE
WR
1~4
1~4
1: WIDE, 2: Normal, 3: Dot by Dot, 4: Zoom
●
FREEZE
FRMD
WR
0~1
0~1
0: OFF, 1: ON
―
Check the resolution
PXCK
R
-
Returns current resolution in the form of hhh, vvv.
TEMPERATURE MONITOR
DSTA
R
0 ~ 4
0: Normal, 1: Abnormal (Power OFF),
2: Abnormal (Currently normal, but temperature abnormality occurs during
use)
3: Abnormal (Low backlight brightness condition)
4: Temperature sensor abnormal
●
TEMPERATURE READ
ERRT
R
Value
Temperature
LAST POWER OFF REASON
STCA
RW
0
0
Initialize
R
1
Power OFF by remote controller or main button
R
2
AC OFF
R
3
Power OFF by RS-232C/LAN
R
4
Standby by No Signal
R
6
Power OFF by temperature abnormal
R
8
Power OFF by schedule
R
10
Power OFF by HDMI CEC
R
11
Power OFF by Crestron
R
12
Power OFF by No Signal
R
21
Auto Backlight Off by Motion sensor