EasyManua.ls Logo

Sharp PN-R706 - Page 45

Sharp PN-R706
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
45
E
Function
Command Direction
Parameter Reply Control/Response contents *
PIP MODES MWIN WR 0-3 0-3 0: OFF, 1: PIP, 2: PbyP, 3: PbyP2
PIP SIZE MPSZ WR 1-64 1-64
PIP POS THE LONGEST
DIRECTION
MHPS W 0-100
R 0-100
THE SHORTEST
DIRECTION
MVPS W 0-100
R 0-100
PIP POS LD+SD BATCH MPOS W 0-100,0-100 Specify the position in MPOSxxxyyy format.
(xxx: Longer side, yyy: Shorter side position)
R 0-100,0-100 Returns a response in (xxx,yyy) format.
(xxx: Longer side, yyy: Shorter side position)
PIP BLEND MWBL WR 0-7 0-7
PIP SOURCE MWIP WR 1 1 DVI-D
2 2 D-SUB[RGB]
3 3 D-SUB[COMPONENT]
10 10 HDMI1
13 13 HDMI2
14 14 DisplayPort
21 21 OPTION (valid when you have used the expansion slot to expand the functions)
SOUND CHANGE MWAD WR 1-2 1-2 1: MAIN, 2: SUB
MAIN POS (Main screen) MWPP WR 0-1 0-1 0: POS1, 1: POS2
PbyP2 POS (Sub screen) MW2P WR 0-2 0-2 0: POS1, 1: POS2, 2: POS3
OTHERS menu
Function
Command Direction
Parameter Reply Control/Response contents *
SCREEN MOTION PATTERN SCSV WR 0-4 0-4 0: OFF, 1-4: PATTERN1-4
MOTION TIME1 MTIM WR 0-20 0-20
MOTION TIME2
(PATTERN1)
MINT WR 10-990 10-990 Per 10 seconds
MOTION TIME2
(PATTERN2-4)
MINT WR 5-20 5-20 Per second
POWER MANAGEMENT PMNG WR 0-1 0-1 0: OFF, 1: ON
CONNECT AUTO INPUT SELECT AICO WR 0-1 0-1 0: OFF, 1: ON
The input via the expansion slot is ignored.
NO SIGNAL AUTO INPUT SEL. AINO WR 0-1 0-1 0: OFF, 1: ON
AUTO INPUT
SELECT PRIORITY
DisplayPort APDP WR 0-10 0-10 0: Not selected by auto input selection, 1-10: Priority
“ERR” when OFF is selected for NO SIGNAL AUTO INPUT SEL..
APOP will result in an error ("ERR") when an optional part that is not a target for
this function is connected.
All input terminals cannot be set to 0 simultaneously.
HDMI1 APH1
HDMI2 APH2
DVI-D APDV
D-SUB APD1
OPTION APOP
LOGO SCREEN BTSC WR 0-1 0-1 0: OFF, 1: ON
SCAN MODE
(HDMI1, HDMI2, D-SUB[COMPONENT],
OPTION (When you have used the expansion
slot to expand the functions.))
SCAN WR 0-2 0-2 0: MODE1, 1: MODE2, 2: MODE3
Initialization/Functional Restriction Setting (FUNCTION) menu
Function
Command Direction
Parameter Reply Control/Response contents *
ALL RESET RSET W 0-1 0: ALL RESET 1, 1: ALL RESET 2 -
ADJUSTMENT LOCK ALCK WR 0-2 0-2 0: OFF, 1:ON1, 2:ON2
ADJUSTMENT LOCK TARGET ALTG WR 0-2 0-2 0: REMOTE CONTROL, 1: MONITOR BUTTONS, 2: BOTH
OSD DISPLAY LOSD WR 0-2 0-2 0: ON1, 1: OFF, 2: ON2
LED OFLD WR 0-1 0-1 0: ON, 1: OFF
TEMPERATURE ALERT TALT WR 0-2 0-2 0: OFF, 1: OSD & LED, 2: LED
STATUS ALERT SALT WR 0-2 0-2 0: OFF, 1: OSD & LED, 2: LED
POWER BUTTON PBTN WR 0-1 0-1 0: MONITOR, 1: EXT. CONTROLLER
EXTERNAL CONTROLLER INPUT PCIP WR 0-4 0-4 0: D-SUB, 1: DisplayPort, 2: HDMI1, 3: HDMI2, 4: DVI-D
(“ERR” when MONITOR is selected for POWER BUTTON.)
SIGNAL RESPONSE LEVEL HDUC WR 1-200 1-200