E
• When installing, removing or moving the monitor, ensure that this is carried out by at least 2 people.
• Be sure to use a wall-mount bracket designed or designated for mounting the monitor.
• This monitor is designed to be installed on a concrete wall or pillar. Reinforced work might be necessary for some materials
such as plaster / thin plastic board / wood before starting installation.
• This monitor and bracket must be installed on a wall which can endure at least 4 times or more the weight of the monitor.
Install by the most suitable method for the material and the structure.
• To attach a VESA-compliant mounting bracket, use M6 screws that are 5/16 inch (8 mm) to 3/8 inch (10 mm) longer than the
thickness of the mounting bracket.
• Do not use an impact driver.
• When moving the monitor, hold the parts marked by
below. Do not hold the LCD panel. This may cause product
damage, failure, or injury.
• After mounting, please carefully ensure the monitor is secure, and not able to come loose from the wall or mount.
• Do not use any screw holes other than VESA holes for installation.
Model PN-Y555 PN-Y475 PN-Y425
Power requirement
AC 100 - 240 V,
1.7
A,
50/60 Hz
AC 100 - 240 V,
1.5
A,
50/60 Hz
AC 100 - 240 V,
1.4
A,
50/60 Hz
Operating temperature * 32°F to 104°F (0°C to 40°C)
Operating humidity 20% to 80% (no condensation)
Power consumption 150 W 135 W 120 W
Dimensions (excluding protrusions) inch (mm)
Approx. 49-3/16 (W) x
2-5/8 (D) x 28-5/16 (H)
(1249 x 66 x 719)
Approx. 42-3/8 (W) x
2-5/8 (D) x 24-1/2 (H)
(1077 x 66 x 622)
Approx. 38-1/8 (W) x
2-5/8 (D) x 22-1/16 (H)
(968 x 66 x 561)
Weight lbs. (kg)
Approx. 55.2 (25.0) Approx. 36.4 (16.5) Approx. 32.0 (14.5)
* Temperature condition may change when using the monitor together with the optional equipments recommended by SHARP. In such cases,
please check the temperature condition specied by the optional equipments.
As a part of our policy of continuous improvement, SHARP reserves the right to make design and specication changes for product improvement
without prior notice. The performance specication gures indicated are nominal values of production units. There may be some deviations from