6
R-508FS
Key Unit
TEST PROCEDURES
PROCEDURE
LETTER
COMPONENT TEST
J KEY UNIT TEST
1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Isolate the key unit with the control panel frame to be tested.
5. Using an ohmmeter and referring to the key unit matrix indicated on the control unit circuit, check the
circuit between the pins of the key unit that correspond to the STOP/CLEAR pad. When the pad is
pressed, the ohmmeter should indicate short circuit. When the pad is released, the ohmmeter should
indicate open circuit. If incorrect readings are obtained, the key unit is faulty and must be replaced. About
the other pads, the above method may be used
6. Reconnect all leads removed from components during testing.
7. Re-install the outer case (cabinet).
8. Reconnect the power supply cord after the outer case is installed.
9. Run the oven and check all functions.
8
POPCORN
DE F R OS T
START
POWER
LE VE L
MIN U T E
PLUS
TIMER
CLOCK
1
4
7
5
2
8
0
9
3
6
COOK
REHEAT
7 6 5 4 3 2 1
91011121314
STOP
CLEAR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp R-508FS and is the answer not in the manual?

Sharp R-508FS Specifications

General IconGeneral
BrandSharp
ModelR-508FS
CategoryMicrowave Oven
LanguageEnglish

Related product manuals