? -9320
3 -9450
TROUBLESHOOTING GUIDE (CONT’D)
PROBLEM
POSSIBLE CAUSE
TEST PROCEDURE OR
CORRECTION
(R-9450 ONLY)
When oven is set for temperature
controlled cooking - (Temperature
probe installed):
“EE” appears in the display.
(Oven does not operate)
Temperature probe open or shorted.
1 Replace probe.
I
,
Slip connector contacts and/or connected
j Replace slip connector and/or
I
wiring open.
; repair wiring.
I
Defective control unit.
/ Procedure N.
I
Temperature control operation.
(CONTINUED)
Temperature appearing in display
is different from food temperature.
Defective temperature probe.
Defective control unit.
Procedure M.
Procedure N,
30