EasyManua.ls Logo

Sharp SB-29S - REMOVE OF TEMP. FUSE ASSY; REMOVE OF THERMOSTAT (42°C, 93°C); REMOVE OF PCB HOT DISPLAY AND PCB COOL DISPLAY

Sharp SB-29S
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
REMOVE OF TEMP. FUSE ASS’Y
1. Disconnect 2 lead wires Temp. fuse ass’y and cut lead wire from the PCB Hot display.
2. Disconnect 2 terminals from thermostat and switch ON/OFF.
2. Remove the screw holding the temp. fuse ass’y to the temp. fuse angle.
3. Remove the temp. fuse ass’y from the temp. fuse angle.
4. Now the temp. fuse ass’y is free.
REMOVE OF THERMOSTAT (42
o
C, 93
o
C)
1. Disconnect 4 terminals from the thermostat.
2. Remove 4 screws holding thermostat to heater tank ass’y.
3. Now the thermostat are free.
Heater tank ass’y
Screw
Thermostat 42
o
C
Thermostat 93
o
C
Terminal
Fig. 8
Fig. 7
REMOVE OF PCB HOT DISPLAY AND PCB COOL DISPLAY
1. Remove the panel B-A in accordance with “REMOVE OF PANEL B-A”.
2. Remove 2 screws holding PCB Hot display and PCB Cool display.
3. Cut lead wires from the PCB Hot display and PCB Cool display.
4. Now the PCB Hot display and PCB Cool display are free.
PCB Hot display
PCB Cool display
Panel-B
Panel-A
Screw
Fig. 9
Thermostat
Temp. fuse angle
Temp. fuse
Screw
Lead wire for
temp. fuse white
Lead wire for temp. fuse white
Lead wire for
temp. fuse white
Terminal
PCB Hot display
Switch ON/OFF

Related product manuals