SJF800SPSL
9 – 2
Buzzer: =0.5 sec ON/0.5 sec OFF, =2 sec ON/0.5 sec OFF
No
.
Status Buzzer LCD
Display
Content
Correspon-
dence
method
- No defects None - - - -
1 F-thermistor system defect EE 01
Defect of each thermistor, short circuit/wire breakage of ther-
mistor wiring and defect of main PWB
[1]
2 R-thermistor system defect EE 02 [2]
3 DEF-thermistor system defect EE 03 [3]
4
Outside temperature-thermistor
system defect
EE 04 [4]
5 Defrost defect EE 07
Wire breakage of fuse•defrost heater, defect of main PWB
(120-minute defrosting has been occurred continuously 2 times
within the past 48 hours.)
[5]
6 F fan motor system defect EE 08
Defect of each fan motor, fan-lock and defect of wiring/main
PWB
(When fan motor is ON, over current or no current is detected.)
[6]
7 C fan motor system defect EE 09 [7]
8 R fan motor system defect EE 10 [8]
9
Ionizer (Plasmacluster) system
defect
EE 11 [9]
10 LCD Display communication defect EE 12
Short circuit/wire breakage of wiring and defect of LCD or main
PWB (Communication with LCD PWB has been abnormal over
3 times within the past 48 hours.)
[10]
11 F-thermistor system defect history EH 61
Defect of thermistor system has been occurred over 1 minute
continuously within the past 48 hours.
[1]
12 R-thermistor system defect history EH 62 [2]
13
DEF-thermistor system defect his-
tory
EH 63 [3]
14
Outside temperature-thermistor
system defect history
EH 64 [4]
15 F fan motor system defect history EH 66
Defect of fan motor has been occurred over 3 times continu-
ously within the past 48 hours.
[6]
16 C fan motor system defect history EH 67 [7]
17 R fan motor system defect history EH 68 [8]
18
Ionizer (Plasmacluster) electrifying
defect history
EH 72
Defect of Ionizer (Plasmacluster) electrifying has been
occurred over 3 times continuously within the past 48 hours.
[9]
19 F-room high temperature history EH 76
Temperature of F-thermistor has been reached over -10°C con-
tinuously for 6 hours or more within the past 48 hours. (except
right after the installation)
[1]
20 R-room high temperature history EH 77
Temperature of R-thermistor has been reached over +10°
C
continuously for 6 hours or more within the past 48 hours.
(except right after the installation)