SJ-WS320T-S
26
After approx. 15 sec., the voltage measured 
across      and      of CN1
(SJ-WS320T/RP320T) or 
across      and      of CN1
(SJ-WP320T/RM320T/WM322T) on the 
main PWB is equal to supplied voltage? 
(e.g. 240 V)
(DEF-thermistor system diagnosis)
Power OFF
Replace DEF-thermistor.
Replace main PWB.
NG?
NG?
NO
NO
YES
YES
Remove 6P connector from E.V. 
cover Assy and measure the 
thermistor resistance between 
 and  .
.03  /  .63
.04  /  .64
(Outside temperature - thermistor system diagnosis)
Replace Display-PWB.
Outside
temperature thermistor 
is installed on 
Display-PWB ass'y.
(Defrosting diagnosis)
.07
Replace main PWB.
Replace fuse Assy.
Replace 
defrost heater.
NO
YES
NO
YES
YES
NO
YES
NO (Open)
Forced defrosting (Measurement is impossible when 
DEF-thermistor is set at 10°C or higher because 
defrosting ends immediately)
Disconnect CN1 from the main PWB. 
Measure the resistance 
between      and      of CN1
(SJ-WS320T/RP320T) or 
between      and      of CN1
(SJ-WP320T/RM320T/WM322T)
on the wiring
Check defrost heater wiring for loose 
connection or disconnection.
Check cause of defrosting failure
· Check door packing
· Check mounting seal of E.V. cover Assy
[
3
]
[
4
]
[
5
]
5.8
approx. 370
(defrost heater 130W)
5
5
6
Turn power OFF. After approx. 30 sec., 
open the refrigerating room door and 
re-energize. (Buzzer beeps continuously)
Between 6P connector 
 
and     on 
E.V. cover Assy is carrying current?
Resistance of 4P connector between
 
 1  
and
  2  
on E.V. cover ass’y is normal? (370    ) 
For the resistance of the thermistor, 
refer to [8] 5. CONVERSION TABLE 
BETWEEN TEMPERATURE AND 
RESISTANCE VALUE
Power off