MICROWAVE MEASUREMENT PROCEDURE
A. Requirements:
1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should
not exceed 1mW/cm
2
at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a
purchaser, and thereafter (through the useful life of the oven), 5 mW/cm
2
at any point 5cm or more from the external surface
of the oven.
2) Safety interlock switches Primary interlock relay and door sensing switch shall prevent microwave radiation emission in excess
of the requirement as above mentioned, secondary interlock switch shall prevent microwave radiation emission in excess of
5 mW/cm
2
at any point 5cm or more from the external surface of the oven.
B. Preparation for testing:
Before beginning the actual measurement of leakage, proceed as follows:
1) Make sure that the actual instrument is operating normally as specied in its instruction booklet.
Important:
Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard for microwave
ovens, 21 CFR 1030.10(c)(3)(i), must be used for testing.
2) Place the oven tray in the oven cavity.
3) Place the load of 275 ±15 ml (9.8 oz) of tap water initially at 20 ±5˚C (68˚F) in the center of the oven cavity.
The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx.
8.5 cm (3-1/2 in.) and made
of an electrically nonconductive material such as glass or plastic.
The placing of this standard load in the oven is important not only to protect the oven, but also to insure that any leakage is
measured accurately.
4) Set the cooking control on Full Power Cooking Mode.
5) Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is completed, replace
it with 275 ml of cool water.
C. Leakage test:
Closed-door leakage test (microwave measurement)
1) Grasp the probe of the survey instrument and hold it perpendicular to the gap between the door and the body of the oven.
2) Move the probe slowly, not faster than 1 in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on the meter.
3) Check for leakage at the door screen, sheet metal seams and other accessible positions where the continuity of the metal has
been breached (eg., around the switches, indicator, and vents).
While testing for leakage around the door pull the door away from the front of the oven as far as is permitted by the closed latch
assembly.
4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm
2
, and that
the secondary interlock switch does turn the oven OFF before any door movement.
NOTE: After servicing, record data on service invoice and microwave leakage report.

Other manuals for Sharp SMC1585BS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp SMC1585BS and is the answer not in the manual?

Sharp SMC1585BS Specifications

General IconGeneral
Stylecounter top
Colorstainless steel
Total Capacity1.5 cu. ft.
Control Optionsreheat, popcorn, +60 sec, auto broil, auto roast, auto bake, auto defrost, preheat, convect, broil, low & high mix
Convectionyes
Power Levels10
Sensor Cookingyes
Quick Startno
Defrostby weight or by time
Control Typetouch control
Timerno
Interior Lightyes
Microwave Power900 watts
Electrical Requirementsac 120v/60hz
Voltage120 volts
Current15
Weight and Dimensions IconWeight and Dimensions
Depth19 inch
Height14 9/10 inch
Width24 7/10 inch