7
Troubleshooting
Problem Cure
Dehumidier does not work
Check that the unit is plugged into the mains supply and turned on.
Check that the water tank is not full. If it is full, empty the tank.
Does not dehumidify
Check that the water tank is installed correctly.
Check that the water tank is not full. If it is full, empty the tank.
Clean the air lter.
Ensure that the air ow through the unit is not obstructed.
Does not remove enough moisture
from the air
Reduce ventilation (closed doors and windows).
Ensure that there are not too many sources of humidity.
Ensure that the unit is not being used to dehumidify a room in excess of the size noted in the
specicaitons.
Unit does not run smoothy on the
castors
Ensure that the castors are clean and not clogged with debris.
What to do if the product interferes with radio or TV reception.
If the dehumidier interferes with radio or television reception, try one or
more of the following measures:
ū Adjust or reposition the receiving antenna.
ū Increase the distance between the product and the radio or TV.
ū Connect the equipment into an outlet on a circuit dierent from that of
the radio or TV receiver.
ū Consult the dealer or a qualied radio or TV technician.
Technical specication
Model UD-P16E-W UD-P20E-W
Dehumidication (Litres per day)
30°C, 80% RH 16 20
27°C, 60% RH 9 11
Rated voltage 220–240V AC /50Hz 220–240V AC /50Hz
Power consumption (W)
35°C, 90% RH 310W 330W
30°C, 80% RH 270W 280W
27°C, 60% RH 230W 250W
Air ow volume (m³/h) 146 175
Room Size (m²) 29 to 38 35 to 46
Refrigerant R290 R290
Refrigerant volume (g) 50 60
Water tank capacity (l) 3,8 3,8
Unit size (W x H x D in mm) 355 x 567 x 259 355 x 567 x 259
Weight (kg) 15,4 15,5
Cord length (cm) 200 200
Standby power (W) 0,25 0,25
NOTE:
ū RH - Relative Humidity
ū Room size based on JEMA (Japan Electrical Manufacturers' Association)
standard.