EasyManua.ls Logo

Sharp VC-MH80

Sharp VC-MH80
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MECHANISM
TROUBLESHOOTING
1.
FFlRON
FAILURE (NO TAPE WINDING)
Press FF key.
Is
mastercam at FF
Does capstan
NO
motor turn in FF (or
+
Are
Vcol2V
and NO
s
Voltage supply
REW)
direction
?
Vcc5V
applied
7
-
system in trouble.
NO
Does loading
motor operate
?
NO
Is voltage applied NO
to loading mbtor
?
-
Voltage supply
system in trouble.
Modes changing
NO
Loading motor is
smoothly through
-
damaged. Replace
cam switch
1
it.
YES
Mode sensor
Loading motor
system in trouble
control system in
+
or master cam
trouble.
malpositioned.
YES
r-l
Replace the
capstan motor.
Are idler gear and
NO
Replace the idler
reel disk in mesh
?
assy.
YES
I--
The cassette tape
is presumably
damaged.
2.
REUFLAY
FAILURE (MODE RELEASE)
4
I
Is the master cam NO
Does loading
NO
Is voltage applied NO
Voltage supply
at
PB
position
?
motor operate
?
to loading motor
?
system in trouble.
I
t
Does capstan
motor turn
?
NO
Are Vcoi 2V and
-
Vcc5V
applied
?
NO
-
Voltage supply
system in trouble.
YES
YES
Replace the
capstan motor.
1
Are idler gear and NO
Replace the idler
reel disk in mesh
?
assy.
1
+
YES
Check main
F%VB.

Related product manuals