1. Remove the body in accordance with “REMOVE OF BODY”.
2. Pull out the lead wires PCB-A CN2 from the PCB-B ass’y.
3. Pry 3 claws of the volume SW. angle-E and remove the PCB-B ass’y from the volume SW. angle-E.
4. Now the PCB-B ass’y is free.
REMOVE OF PCB-B ASS’Y
Fig. 27
Back cover
Volume SW. angle-E
Claw of volume SW. angle-E
PCB-B ass’y
Lead wires for PCB-A CN2
1. Remove the body in accordance with “REMOVE OF BODY”.
2. Pull out all the lead wires from the PCB-A.
3. Remove 3 screws holding the PCB-A.
4. Now the PCB-A is free.
REMOVE OF PCB-A
Fig. 26
Screw
Back cover
PCB-A