[Adjustmentofballastunitoutputpower(lamppower)]
1.Listofpartsrequiringadjustment
Whenreplacingthefollowingparts,adjusttheballastunitoutputpower(lamppower).
2.Adjustmentjigs
Thefollowingjigsarerequiredforadjustingtheballastunitoutputpower(lamppower).
3.Ballastunitoutputpower(lamppower)adjustmentmethod
Adjusttheballastunitoutputpower(lamppower)inthefollowingmethod.
[Adjustmentmethod]
(1)Unplugtheballastunitlampcable(QCNW-D573WJQZ)oftheXR10/20projectorfrom
thelampandconnectthecabletotheconnectingcord(QCNW-E007WJZZ).
(2)Connecttheconnectingcord(QCNW-E007WJZZ)totheadjustmentjig
(RUNTZA018WJZZ).
(3)ConnectTP1oftheadjustmentjig(RUNTZA018WJZZ)tothenegativeterminalofthe
testerandTP2tothepositiveterminal.
(4)TurnontheXR10/20projector.
(5)Agetheprojectorfor60secondsormore.
(6)Adjustthevolumeresistor(R7728)oftheballastcontrolPWB(DUNTKD148WEF0)so
thatthevoltageofthetesterreaches83±0.5V.
Adjustmentvalue:83±0.5V
[Cautions]
(1)Cautionforelectricshock:DonottouchthetestpointsTP1andTP2oftheadjustment
jigwhensupplyingpowersinceahighvoltageandlargecurrentisappliedtothem.
(2)Cautionforheat:Becarefulthattheresistanceloadoftheadjustmentjigproducesahigh
temperaturewhensupplyingpower.
(3)Connectionofthelampcable:Checkthatthelampcableandconnectingcord(QCNW-E
007WJZZ)areconnectedsecurely.
Poorconnectionmaycausesmokingorignitionduetoarcdischarge.
[Settingmethod]
Tester
(Voltage)