31
XG-MB50X
XR-11XC
XR-10X/S
XR-20X/S


Is 6 V applied to TL1702
and 13 V to TL1703?
Is approx.6Vapplied to
TL1742?

Is 1.5 V applied to
TL1741?
Go to "Power supply
ballast PWB check".

Check IC1742 and
peripheral circuits.

Check IC1741 and
peripheral circuits.

Is 3.3 V applied to
TL1762?

Check IC1763 and
peripheral circuits.
Is 2.5 V applied to
TL1763?

Check IC1762 and
peripheral circuits.

Is 5 V applied to TL1791?

Check IC1791 and
peripheral circuits.

Is 3.3 V applied to
TL1792?

Check IC1792 and
peripheral circuits.

Is 12 V applied to
TL1761?

Check IC1761 and
peripheral circuits.

  

Is 3.3 V applied to pin(1)
of IC1743?

Check IC1743 and
peripheral circuits.

Is 3.18 V applied to pin(1)
of IC2001?

Check IC2001 and
peripheral circuits.

Is 3.3 V applied to pin(3)
of S2001?

Check that it is set to the N
side. Or remove S2001.

Is rectangular wave of 50
MHz sent to X2251 pin(3)?


Check IC2002, IC2262,
IC2263 and peripheral
circuits.
Check X2251 and
peripheral circuits.