Caution
Do not operate the generator/
welder, or any other appliance,
before you have read and
understand the instructions for use
and keep near for readily use
OWNERS MANUAL
GENERATOR / WELDER
DGW310DMC
DGW310MC
Sound Proof
Vertical, Water-Cooled
4-Cycle Diesel Engine
Table of Contents
1. Safety Guidelines ···················································2
2. Specifications ·························································6
3. Use ···········································································7
4. Parts ········································································7
5. Incorporated ···························································10
5-1
Eco Welding 10
5-2
Display 10
5-3
Frequency Change 10
5-4
Monitor Lamp
10
5-5
Remote Control (Option) 12
5-6
Earth Leakage Relay/Grounding 13
5-7
Slow-Down Feature 15
6. Initialization & Pre-check ·······································16
6-1
Checking Engine Oil 16
6-2
Checking Coolant/Water 17
6-3
Checking Fuel 18
6-4
Leakage Check for the above 18
6-5
Checking Battery 19
7. Operation ································································20
7-1
Start 20
7-2
Stop 22
8. Welding Operation ··················································22
8-1
Selection – Welding Cable 22
8-2
Polarity 23
8-3
Connection – Welding Cable 23
8-4
Welding 24
9
Generator Operation ·············································26
9.1
Output Range 26
9-2
Output Limitation 27
9-3
Operation 28
10
Simultaneous Use – Weld & Generate ··············30
11
Checking & Maintenance ····································31
12
Long-term Storage ··············································36
13
Trouble Shooting ················································37
14. Warranty Sheet (Type B) ········································39
CERTIFIED

Other manuals for Shindaiwa DGW310DMC

Questions and Answers

  • K
    Kristin MarshallSep 23, 2025
    What to do if unable to adjust welding current by remote controller on Shindaiwa Portable Generator?
    • T
      Timothy SaundersSep 23, 2025
      If you're unable to adjust the welding current by remote controller on your Shindaiwa Portable Generator, disconnect any AC load connected to the remote control receptacle. Also, ensure the switch (breaker) on the cord reel is turned "ON".
  • M
    Matthew JenkinsAug 23, 2025
    Why is the welding arc weak on my Shindaiwa Welding System?
    • A
      Ashley McculloughAug 23, 2025
      A weak welding arc on your Shindaiwa Welding System can stem from several issues. Check that the Output Selector Switch is set to 'SINGLE' or 'REGULAR', not 'ECO' or 'DUAL'. Also, ensure the Frequency Switch is at '60Hz', not '50Hz'. Adjust the Current Dial clockwise to increase the current. Poor cable connections can also weaken the arc, so ensure they are securely connected. Verify that the welding cable's diameter and length are appropriate. Make sure there is good contact with the material being welded. Stop using AC output during welding.
  • B
    Brian JohnsonAug 25, 2025
    What to do if the starter motor will not start on my Shindaiwa Welding System?
    • A
      Alexis CherryAug 26, 2025
      If the starter motor on your Shindaiwa Welding System does not start, it could be due to a weak or dead battery. Try recharging the battery first. If that doesn't work, the battery may need to be replaced.
  • P
    patricia77Aug 26, 2025
    What to do if the engine starts but stalls immediately on my Shindaiwa Welding System?
    • V
      vherreraAug 27, 2025
      If your Shindaiwa Welding System's engine starts and then stalls immediately, it could be due to insufficient oil. Replenish the oil. It could also be caused by high water temperature or insufficient coolant/water; maintain the rated coolant/water level. Another possible cause is an inability to charge; in this case, repair is needed.
  • G
    garrett01Aug 27, 2025
    Why is the welding arc too strong on my Shindaiwa DGW310DMC Welding System?
    • S
      Sheila HicksAug 27, 2025
      If the welding arc is too strong on your Shindaiwa Welding System, it might be because the Output Selector Switch is set to 'SINGLE' or 'REGULAR'. Try changing it to 'ECO' or 'DUAL'. Also, the Current Dial position could be too high, so turn it counterclockwise to reduce the current.
  • D
    Donald PerezSep 17, 2025
    How to reduce excessive welding arc on Shindaiwa Portable Generator?
    • K
      Kathryn DavisSep 18, 2025
      If the welding arc is excessive on your Shindaiwa Portable Generator, the output selector may be set to "SINGLE". Change it to "ECO" or "DUAL". Also, the output control dial position may be incorrect; turn it counterclockwise.
  • A
    Angela BrownSep 14, 2025
    Why is my Shindaiwa Portable Generator emitting excessive black smoke?
    • M
      Mark ReidSep 14, 2025
      If your Shindaiwa Portable Generator is producing excessive black smoke from the muffler, it's likely due to overloaded use. Ensure you operate the machine within its rated output.
  • K
    Karen NelsonSep 15, 2025
    What to do if Shindaiwa Portable Generator engine does not stop?
    • K
      Kevin JimenezSep 15, 2025
      If your Shindaiwa Portable Generator engine won't stop, it may be due to a stop solenoid malfunction. Turn the fuel lever to "CLOSE" to stop the engine and then repair the solenoid.
  • J
    jennifersmithSep 6, 2025
    Why won't my Shindaiwa Portable Generator start?
    • D
      David MullinsSep 6, 2025
      If your Shindaiwa Portable Generator's engine won't start, several factors could be at play. First, ensure the fuel lever on the fuel filter is open. Secondly, check that you have sufficient fuel. If the fuel is contaminated with water or dust, drain the tank and clean the fuel strainer. Finally, inspect the fuse and repair it if it's burnt.
  • S
    Stephen HughesSep 3, 2025
    Why does the slow-down not activate on my Shindaiwa DGW310DMC?
    • A
      Ashley EdwardsSep 3, 2025
      The slow-down feature on your Shindaiwa Welding System might not activate if there's a welding cable short-circuit; repair the short-circuit. Also, if the power consumption of the load is 0.5A or below, the slow-down may not activate; in this case, change the slow-down switch to 'OFF'.

Shindaiwa DGW310DMC Specifications

General IconGeneral
Rated Output3.1 kVA
Frequency50/60 Hz
Duty Cycle60%
Engine TypeDiesel, 4-stroke
Welding Current Range30-310 A
Electrode Diameter2.0-5.0 mm