4008 RV By-Pass Pump By SHURflo
Installation & Maintenance Manual
Installation Preparation
The goal of installation is to provide a quiet, easy-
to-maintain installation with good flow and low
backpressure. This can be accomplished with
the following guidelines:
Mount on a solid surface in an accessible
location for strainer cleaning and pump main-
tenance.
Use flexible high-pressure hose on the pump
inlet and outlet [such as SHURflo Kit 94-591-
00]. The pumps ports and strainer should not
be connected to plastic or rigid pipe, or the
pump's normal motion will transmit through
rigid plumbing causing noise, and possibly
loosening or cracking components.
Pump must use an adequate 50-mesh strainer
[such as SHURflo 255 series strainers].
Use a minimum of 1/2" [13mm] Inner Diame-
ter plumbing. Smaller ID plumbing will cause
cavitation, high backpressure, low flow and
noise.
No need for an accumulator with by-pass pumps.
Pump is designed for intermittent duty only: Do not use these pumps for running a Reverse-Osmosis [RO] Filtration
System. High pressure-continuous duty usage will shorten the life of the pump and is not covered under warranty.
Wire Size is 16 GA MINIMUM , 12GA is recommended---See Wire Chart in Electrical Section for minimum sizing.
Minimum power requirement is a 10 Amp circuit.
Reduce restrictions on inlet and outlet. This includes small inner diameter shut-off valves, winterizing valves and
elbows.
If the RV has an Intellitec Pump Controller, it must be rated at 10 or 15 amps; If the controller is rated at 7.5 Amps, a
new controller or a high-amp relay must be used.
Mounting
Mount the pump within 6 feet of the tank for best performance and pump life. The pump will pull farther, but the farther it
pulls the more work it does, increasing vibration and noise, and reducing the output and pump life.
Mount pump in a space of at least 1 cubic foot for adequate ventilation to prevent overheating.
Pump may be mounted in any position.
Mount pump for easy access for cleaning strainer, maintenance and service.
Mount pump on a solid surface to prevent vibration and noise.
Electrical
The pump works best on an individual filtered circuit, protected by the recom-
mended fuse or breaker specified on the label.
A 15-Amp switch is recommended and should be on the positive lead.
Wire Sizing: Proper wire sizing is required for good pump operation. If the
wire is too small, low voltage will affect the pump performance and can create
a fire hazard.
SHUT OFF POWER TO THE PUMP WHEN LEAVING THE RV UNATTENDED.
Plumbing
Installation of a strainer is required to prevent debris from entering the pump.
For noise and vibration reduction we recommend at least 18 in. [.5 M] of 1/2" [13mm] I.D. flexible high-pressure hose to
both ports. The pump ports and strainer should not be connected to plastic or rigid pipe. This hose should be anchored
where it meets the hard plumbing to reduce plumbing vibration.
SWIVEL FITTINGS
HIGH-PRESSURE
FLEXIBLE HOSE
SWITCH
POTABLE H20 INLET
16GA [1,29mm] min.
GROUND
STRAINER
Typical Pump Installation
Installation Guidelines
Solid surface within 6 feet of tank • Accessible location
Minimize flow restrictions in the system Strainer on pump inlet
No accumulator needed Properly sized wiring
Flexible hose on inlet and outlet Proper electrical protection
Minimize plumbing elbows and valves Properly sized plumbing
Minimum Wire Size for a 10% voltage drop on a
12VDC, 10 Amp Circuit. Length is the distance from
the power source to pump and back to ground.
911-1008-D Page 1 of 3
Feet [Meters] AWG [mm²]
0 - 25 [0 - 7.6] 16 [1.3]
25 -50 [7.6 - 15.2] 14 [2.1]
50 - 70 [15.2 - 21.3] 12 [3.3]
70 -110 [21.3 - 33.5] 10 [5.3]
FUSE
CONNECTOR
SOLID SURFACE

Questions and Answers

Summary

Installation Preparation

Mounting

Guidelines for mounting the pump within 6 feet of the tank for optimal performance and longevity.

Electrical Requirements

Proper wiring, circuit protection, and switch recommendations for pump operation.

Plumbing Installation

Recommendations for plumbing, including flexible hose and strainer for noise and vibration reduction.

Pump Operation

By-Pass Adjustment

Information on the by-pass valve adjustment, its function, and potential issues.

Maintenance Procedures

Sanitizing the System

Step-by-step guide for sanitizing potable water systems using bleach.

Winterizing the System

Instructions for draining the pump and system to prevent freeze damage.

Troubleshooting Guide

Pump Will Not Start;Blows Circuit

Diagnosing issues related to electrical connections, fuses, or motor problems.

Pump Will Not Shut-Off

Troubleshooting why the pump runs continuously when the faucet is closed.

Will Not Prime;Sputters

Identifying causes for the pump not priming or sputtering during operation.

Noisy or Rough Operation

Addressing issues causing vibration, noise, or rough pump performance.

Leaks from Pump Head or Switch

Diagnosing leaks originating from the pump head or the pressure switch.

Rapid Cycling

Finding the cause of the pump cycling on and off too frequently.