IO-Link interface
44 © SICK AG • Subject to change without notice • 8014868/YIF1/2020-10-19
Index
decimal
(hex)
Description Format Access Value range Example Remarks
64 (0x40) Integration time
measurement or
output rate
UINT8 R/W • 0
1
2
3
4
5
6
7
8
DT35 and DS35 red
laser, class 1 devices:
Integration time mea-
surement or output
rate 2
n
* 2 ms,
All other devices:
Integration measure-
ment or output rate 2
n
* 1 ms
Devices up to date
code 2033xxxx:
Writable only if “0:
Expert” was selected
for index “103”.
Devices from date
code 2034xxxx:
Writing automatically
generates the selec-
tion “0: Expert" for
index “103”.
67 (0x43) Averaging UINT8 R/W • 1: OFF
2: Filter depth 2
4: Filter depth 4
8: Filter depth 8
16: Filter depth 16
Sliding averaging over
x measured values. Af-
fects only process data
and analog output, not
switching behavior.
Devices up to date
code 2033xxxx:
Writable only if the “0:
Expert” was selected
for index “103”.
Devices from date
code 2034xxxx:
Writing automatically
generates the selec-
tion “0: Expert” for
index “103”.