Display behavior in the respective mode:
When using the “Transponder Presence” condition, the digital output is activated
as soon as a tag is located in the field (0x00).
When using the “Compare Data” condition, the device compares the data read
from the transponder to the reference data. To do so, the device compares the
data of the first four bytes of a memory block. Define the reference data for
the device in subindex 0x03. The data structure of the device is structured in
hexadecimal format and you have to ensure the data is input correctly.
Example: filter definition for a block
°
Data in transponder: 0x01 0x02 0x03 0x04
°
Input for filtering: 0x04 0x03 0x02 0x01
The 0x02 and 0x03 indices make it possible to use the alarm function of the
device in SIO mode. Description of the function see "", page 45.
Configure the polarity for the events in SIO mode in subindex 3. The data retention time
specifies how long the device keeps the level of the output after the SIO condition is no
longer met.
C/Q1 SIO mode works on pin 4 of the M12 plug connector, in classic SIO mode in
accordance with IEC61131-9. C/Q2 mode uses pin 2 as a digital output.
If SIO mode is selected in the IO-Link master: Q1 & Q2 can be configured in
IO-Link mode (e.g., via SOPAS ET).
If IO-Link mode is selected in the IO-Link master: Configuration and data transfer
can occur via IO-Link.
In order to use pin 2 as a digital input in the available IO-Link master, check the
configuration options of your IO-Link master.
For more detailed information on both modes, see see "Process data", page 36.
Index dec
(hex)
Name Format
(Offset)
Lenght Access
1)
Default
Value
Value / Range Remark [Unit]
65 (0x41) Configure SIO-mode Record 15
Byte
rw Configuration of the
device for SIO mode
operation
1 (0x01) Evaluation condition
C/Q1
Bit (112) 8 Bit rw 0 0 = Transponder
Presence
1 = Compare data
2 = Alarm 1
3 = Alarm 2
4 = SIO deactivated
2 (0x02) C/Q1 memory
address for compare
data condition
Bit (104) 8 Bit rw 0 Transponder memory
block adress for "Com‐
pare Data"
3 (0x03) C/Q1 comparison
data for compare
data mode
Bit (72) 32 Bit rw 0 Comparison data value
stored in read-write
device to be compared
to transponder data
8 OPERATION
42
O P E R A T I N G I N S T R U C T I O N S | RFH5xx 8025309/1KDE/2023-12-19 | SICK
Subject to change without notice