Using SINAMICS G120 / G120C / S120 Blocksize converters
in marine applications
Question and Answer IconNeed help?

Do you have a question about the Siemens 6SL3210-1KE23-2AF1 and is the answer not in the manual?

Siemens 6SL3210-1KE23-2AF1 Specifications

General IconGeneral
Article Number6SL3210-1KE23-2AF1
Protection ClassIP20
Frame sizeFSA
Internal air coolingYes
Voltage Supply380 ... 480 V 3 AC
Storage Temperature-40 ... 70 °C
Relative Humidity5 ... 95 %
Input voltage380 ... 480 V 3 AC
Braking chopperIntegrated
Output voltage0V - Input voltage

Summary

Legal information

Warning notice system

Explains the meaning and grading of warning notices used to ensure personal safety and prevent property damage.

Safety information

Introduction

Components for marine applications

PM240-2 Power Modules

Details the PM240-2 Power Modules, including voltage, frame size, power range, and integrated filter options.

Control Units / Control Unit Adapter

Lists and describes various Control Units (CU230P-2, CU240E-2, CU250S-2) and Control Unit Adapters (CUA).

Operator Panels

Overviews the BOP-2 and IOP-2 operator panels, their use, and article numbers for marine applications.

G120C compact converter

Details the G120C compact converter specifications, including voltage, frame size, power range, communication, and filter options.

Referencing the standard documentation of the components

Presentation of the "PM240" system being considered

System configuration for marine applications

Marine-specific application conditions

Marine-specific installation regulations

Reinforced control cabinet design

Explains the need for reinforced control cabinet design due to vibration stress and provides an example using Rittal TS8.

Integration of the components in the cabinet

Details how to install Control Units, Power Modules, and adapters in the control cabinet to manage vibration stress.

Operator panel installed in the cabinet doors

Describes the installation of BOP-2 or IOP-2 operator panels in control cabinet doors using a specific mounting kit.

Cooling - control cabinet ventilation

Outlines requirements for ventilating control cabinets to dissipate power loss, specifying air intake and discharge locations.

External auxiliary power supply

Explains connecting an external 24-V-DC auxiliary power supply for Control Units and its specifications.