Service Nur für den internen Gebrauch
A31003-H3590-S100-7-7620, 06/2012
12-78 HiPath 3000/5000 V9, Service documentation
service.fm
Guided Maintenance
20-017 !int. charg buf
ovflw
Internal call data
memory overflow.
Read out call data.
If the error persists, check
the call data application in-
terface.
20-029 !Forced trunk dis-
connection
Manual line re-
lease (for U.S.
only).
None
20-032 !CDR Mem. alloc.
failed
Advanced call data
memory cannot be
created.
System with MMC
module: MMC module
is faulty. Replace the
MMC.
HiPath 2000: File sys-
tem in flash is full or
faulty.
20-033 !CDR Cache al-
loc. failed
Read cache for
reading out CDR
data cannot be cre-
ated.
Perform a hard restart
(normally occurs automati-
cally).
This is caused
by insufficient
system memory
capacity.
20-034 !CDR Data write
failed
Error while writing
CDR data to the
advanced call data
memory.
MMC module: If neces-
sary, read out call data via
TFTP. The internal admin-
istration structure is also
corrected, if this is re-
quired.
20-035 !CDR Adm. write
failed
Error while writing
the administration
structure to the ad-
vanced call data
memory.
MMC module: If neces-
sary, read out call data via
TFTP. After this, replace
the MMC module.
20-036 !CDR Data read
failed
Error while reading
CDR data from the
advanced call data
memory.
Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
Table 12-7 HiPath 3000 Class B Error Messages
No. HiPath 3000/
5000 Manager E:
Event Log Entry
Meaning Required Measures Note