service.fm
A31003-H3590-S100-7-7620, 06/2012
HiPath 3000/5000 V9, Service documentation
12-79
Nur für den internen Gebrauch Service
Guided Maintenance
20-037 !CDR Adm. read
failed
Error while reading
administration
structure from the
advanced call data
memory.
Set up a trace using infor-
mation from BLS.
Create a stack dump.
Save a snapshot.
20-038 !CDR Data de-
tected
An advanced call
data memory was
found during sys-
tem startup.
None
20-039 !CDR Data over-
flow
The advanced call
data memory is
full.
Read out call data.
20-040 !CDR Mem. allo-
cated
The advanced call
data memory was
successfully creat-
ed.
None
20-041 !CDR Mem. re-
leased
The advanced call
data memory was
temporarily re-
leased.
None This message is
issued after the
call data memo-
ry has been
completely read
out. It must be
followed by the
“CDR Mem. allo-
cated” message.
Table 12-7 HiPath 3000 Class B Error Messages
No. HiPath 3000/
5000 Manager E:
Event Log Entry
Meaning Required Measures Note

Table of Contents