EasyManua.ls Logo

Siemens iQ500 KA93GAI30N - Appliance Installation Guide Continued; Ambient Temperature and Ventilation; Installing Rear Spacers; Installation Dimensions

Siemens iQ500 KA93GAI30N
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
en
6
Observe ambient temperature and
ventilation
Ambient temperature
The climate class can be found on the rating plate. The
climate class indicates within which ambient temperat
ures the appliance can be operated. The rating plate
is located in the refrigerator compartment at the right
side.
Climate class Permitted ambient temperature
SN +10 °C to 32 °C
N +16 °C to 32 °C
ST +16 °C to 38 °C
T +16 °C to 43 °C
Note:
The appliance is fully functional within the room
temperature limits of the indicated climatic class.
If an appliance of climatic class SN is operated at
colder room temperatures, the appliance will not be
damaged up to a temperature of +5 °C.
Ventilation
Never cover the ventilation openings on the rear of the
appliance. Conduction of the heated air must not be
obstructed. Otherwise, the refrigeration unit will have to
work harder. This increases power consumption.
Installing the spacers
Remove the two screws using a screwdriver. Take the
spacers out of the bag. Secure the spacers to the rear
of the appliance using the screws. This ensures that
thereisaminimumdistancebetweentheappliance
and the wall.
Installation dimensions
908
1787
387
763
908
1730
629
708
515
min. 53
max. 62
Door opening angle
277
418
908
28
135°
130°
1603
763
708
629
(B)
a
b
90°
90°
135°
130°
(A) (A)
(B)
a b
600
A: unit depth
B: wall
Drawers can be pulled out
with door open to 90°.
Drawers can be taken out
with door completely opened.
650
700
50
50
53
75
418
50
50
96
A
B