en Disposal
16
Fault Cause and troubleshooting
/ The operating voltage is incorrect and outside of the normal operating range.
Contact your energy supplier.
/ The hob is not connected correctly.
Disconnect the hob from the mains. Connect the hob in accordance with the circuit dia-
gram.
Demo mode is activated.
Disconnect the hob from the mains. Wait for 30 seconds and connect the hob. Touch
any sensor in the next threeminutes. Demo mode is deactivated.
17.3 Normal noises from your appliance
An induction hob may sometimes cause noises or vi-
brations, such as buzzing, crackling, hissing noises, fan
noises or rhythmic noises.
18  Disposal
18.1 Disposing of old appliance
Valuable raw materials can be reused by recycling.
1.
Unplug the appliance from the mains.
2.
Cut through the power cord.
3.
Dispose of the appliance in an environmentally
friendly manner.
Information about current disposal methods are
available from your specialist dealer or local author-
ity.