K42 7
GB
English
Setting the codes
Move the jumpers next to the digits that should
make up codes 1 and 2 respectively. NOTE! If only
one code (Code 1) is to be used, link terminal block
nos. 8 and 9 together. Do NOT leave any jumpers
off.
1
Example (see figure on page 4):
Code 1: 0123 Code 2: 4589
Timing the codes
The codes can be disabled for certain periods, e.g.
from a time clock. When terminal block nos. 7 and 9
are linked, code 1 is disabled. When terminal block
nos. 8 and 9 are linked, code 2 is disabled.
2
3
Remote opening/Exit Request
Between terminal block nos. 6 and 9, a time clock
(the lock is unlocked, e.g. daytime) or a N/O
pushbutton (exit request) can be connected.
4
Lock activating time
Set the lock activating time using the knob, variable
1-30 seconds. Normal time approx. 7 seconds.
Background Lighting
Set the jumper to ON to switch on the background
light for the keyboard.