Circulating-air mode
An activated carbon lter CLEAN
AIR MODULE must be tted for this
operating mode
The complete installation set and
replacement lters can be obtained
from specialist outlets. VIB: LZ56700.
The extractor-hood fan extracts the
kitchen vapours which are puried in
the grease lter and activated carbon
lter and then conveyed back into the
kitchen.
The grease lter absorbs the grease
particles in the kitchen vapours.
The activated carbon lter binds the
odorous substances.
If no activated carbon lter is installed,
it is not possible to bind the odorous
substances in the cooking vapours.
Changing the electronic control
systemto recirculating mode:
The standard factory setting is
foroperation in exhaust-air mode.
To change the mode, the extractor
hoodmust have been connected up
andshould be switched off.
Simultaneously press buttons O and
until comes on. Then release
thebuttons.
goes out shortly afterwards.The
electronic control system will
thenhave been set to recirculating
mode.
By repeating steps 1and 2, you
canchange the electronic control
systemback to exhaust-air mode (
in display).
Caution:
As the lter becomes more and more
saturated with grease, there is an
increased risk of re and the function of
the extractor hood may be impaired.
Important:
Change the activated carbon lter
promptly to prevent the risk of re from the
accumulation of heat when deep-fat frying
or roasting.
Saturation indicator:
When the activated carbon lter becomes
saturated, the display symbol
lights up
and a signal sounds. The signal is
switched off when the fan is switched off.
The activated carbon lter should be
replaced straight away.
Replacing the activated carbon lter:
During normal operation (1 to 2 hours
per day) the activated carbon lters
should be replaced approximately 1 x
year.
A replacement lter can be obtained
from any authorized dealer.
Use original lters only.
By doing so you will obtain maximum
performance from your extractor hood.
Disposing of the old activated carbon
lter:
There are no pollutants in the
activated carbon lters. They can
therefore be disposed of as part of
your normal domestic refuse.