EasyManua.ls Logo

Siemens LI97SA531 - Page 13

Siemens LI97SA531
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation instructions en
13
12.8 Installation
Checking the unit
1.
Check whether the fitted unit is level and has suffi-
cient load-bearing capacity.
The max. weight of the appliance is 18kg.
2.
Ensure that the fitted unit is heat-resistant up to
90°C.
3.
Ensure that the fitted unit is still stable after the cut-
outs have been made.
4.
Ensure that the fitted unit complies with the following
dimensions:
Width 600mm
Depth Min. 320mm
With lowering frame:
Min.350mm
Position Min. 390mm
With CleanAir circulat-
ing-air set, min. 600mm
Wall thickness 16mm or 19mm
Preparing the units
Requirement:The unit is suitable for the
→"Checking the unit", Page13 installation.
1.
Cover the hob to prevent damage.
2.
Ensure that the stability of the fitted unit is guaran-
teed after the cut-outs have been made.
3.
If the cabinet is more than 310mm deep, remove
part of the back panel.
4.
Create the cut-out for the pipe connection.
5.
If the cabinet base is in place, remove it.
6.
Remove any shavings.
7.
Use the enclosed mounting part to mark the fasten-
ing points on the inside of the cabinet and use a
bradawl to make indentations where the holes are
to be.
8.
19mm wall thickness: Open up the spacers on
both of the mounting parts.
9.
Screw the mounting parts to the body on the left
and right.
10.
Remove the limit stops from the bottom of the
mounting parts.
Preparing the appliance
1.
Insert the holders for the wall edging strip on the
outside rear of the appliance into the cut-outs and
fold them in to the centre of the unit.
2.
Use the screws provided to secure the handle strip
to the filter pull-out.

Other manuals for Siemens LI97SA531

Related product manuals