en Installation instructions
14
¡ To prevent condensate from returning, fit the ex-
haust pipe with a 1° gradient from the appliance.
13.8 Installation
Checking the unit
1.
Check whether the fitted unit is level and has suffi-
cient load-bearing capacity.
The maximum weight of the appliance is 18kg.
Note:Note the furniture manufacturer's specifica-
tions with regard to the load-bearing capacity of the
fitted unit.
2.
Ensure that the fitted unit is heat-resistant up to
90°C.
3.
Ensure that the fitted unit is still stable after the cut-
outs have been made.
4.
Ensure that the fitted unit complies with the following
dimensions:
Width 600mm
Depth Min. 320mm
With lowering frame:
Min.350mm
Position Min. 390mm
With CleanAir circulat-
ing-air set, min. 600mm
Wall thickness 16mm or 19mm
Preparing the units
Requirement:The unit is suitable for the installation.
→"Checking the unit", Page14
1.
Cover the hob to prevent damage.
2.
Ensure that the stability of the fitted unit is guaran-
teed after the cut-outs have been made.
3.
If the cabinet is less than 320mm deep, remove
part of the back panel.
4.
Create the cut-out for the pipe connection.
5.
If the cabinet base is in place, remove it.
6.
Remove any shavings.
7.
Use the enclosed mounting part to mark the fasten-
ing points on the inside of the cabinet and use a
bradawl to make indentations where the holes are
to be.
8.
19mm wall thickness: Open up the spacers on
both of the mounting parts.
9.
Screw the mounting parts to the body on the left
and right.
10.
Remove the limit stops from the bottom of the
mounting parts.