EasyManuals Logo

Siemens LR97CAQ50 User Manual

Siemens LR97CAQ50
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
en Basic operation
8
As soon as the ventilation time ends, the LED for the
fan setting you have selected goes out. LED6 contin-
ues to flash.
8.11 Sensor control
1
In automatic mode, a sensor in the appliance detects
the intensity of the cooking and roasting fumes. De-
pending on the setting of the sensor sensitivity, the op-
timum fan setting is automatically switched on.
If the sensor control system reacts too weakly or too
strongly, the setting for the sensor sensitivity may
change.
¡ Default setting: Fan setting3
¡ Lowest setting: Fan setting1
¡ Highest setting: Fan setting5
8.12 Setting the sensor control
1
Requirement:The appliance is switched off.
1.
Press and hold and for approx. 3 seconds.
2.
Press or to change the setting.
To cancel the setting, press ⁠.
3.
To save the setting, press and hold and for ap-
prox. 3 seconds.
Or wait approx. 10seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
8.13 Setting the saturation indicator
The saturation indicator must be adjusted depending
on the filter used.
Requirement:The appliance is switched off.
1.
Press and hold and for approx.three seconds.
To set circulating-air mode (non-regenerable fil-
ter), press ⁠/ until LED2 lights up in the LED
display.
To set circulating-air mode (non-regenerable fil-
ter), press ⁠/ until LED3 lights up in the LED
display.
To convert the electronic control back to opera-
tion without the air recirculation filter, press ⁠/
until LED1 lights up on the LED display.
2.
To save the setting, press and hold and for ap-
prox. three seconds.
Or wait approx. 10seconds until the setting is
saved automatically.
To cancel the setting, press ⁠.
a A signal tone sounds as soon as the selected set-
ting is saved.
8.14 Resetting the saturation indicator
After cleaning the grease filter or after changing the
odour filter, the saturation indicator can be reset.
Requirements
¡ After the appliance has been switched off, LED1
flashes in the LED display for the grease filter satura-
tion display and/or LED2 flashes for the saturation
indicator for the odour filter.
¡ A repeated signal tone sounds.
Press .
a The saturation indicator is reset.
8.15 Switching on the lighting
The lighting can be switched on or off independently of
the ventilation.
Press ⁠.
Note:Colour temperature settings are available in the
HomeConnect app provided the appliance has this
function.
8.16 Setting the brightness
Press and hold or ⁠.
Note:Colour temperature settings are available in the
HomeConnect app provided the appliance has this
function.
8.17 Switching on the button tone
The button tones can be switched on.
Requirement:The appliance is switched off.
1.
Press and hold and for approx.three seconds.
a In the LED display, the LED for the setting that is
currently selected lights up.
2.
Press or until LED1 lights up in the LED dis-
play.
To cancel the setting, press ⁠.
3.
To save the setting, press and hold and for ap-
prox. threeseconds.
Or wait approx. 10seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
8.18 Switching the button tone off
The button tones can be switched off.
Note:Signal tones for the appliance are always
switched on and cannot be switched off.
Requirement:The appliance is switched off.
1.
Press and hold and for approx.three seconds.
a In the LED display, the LED for the setting that is
currently selected lights up.
2.
Press or until LED2 lights up in the LED dis-
play.
To cancel the setting, press ⁠.
3.
To save the setting, press and hold and for ap-
prox. threeseconds.
Or wait approx. 10seconds until the setting is
saved automatically.
a A signal tone sounds as soon as the selected set-
ting is saved.
1
Depending on the appliance specifications

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens LR97CAQ50 and is the answer not in the manual?

Siemens LR97CAQ50 Specifications

General IconGeneral
TypeCeiling built-in
Cord length1.3 m
CertificationCE, VDE
Product colorBlack, Silver
Built-in display-
Exhaust connection diameter150 mm
Noise level56 dB
Intensive speedYes
Number of speeds3
Type of extractionDucted/Recirculating
Noise level (low speed)41 dB
Maximum extraction power760 m³/h
Noise level (high speed)63 dB
Maximum recirculating power560 m³/h
Noise level (intensive speed)68 dB
Fluid dynamic efficiency classA
Grease filtering efficiency classE
Minimum distance from electric hob650 mm
Bulb typeLED
Bulb power3 W
Illuminance659 lx
Number of bulbs4 bulb(s)
Grease filter typeStainless steel
Motor power174 W
Connected load160 W
AC input voltage220 - 240 V
AC input frequency50 - 60 Hz
Annual energy consumption31.8 kWh
Weight and Dimensions IconWeight and Dimensions
Depth500 mm
Width900 mm
Height300 mm
Weight26900 g
Installation compartment depth487 mm
Installation compartment width888 mm
Installation compartment height299 mm