Before using for the first time en
7
7  Before using for the first time
Configure the settings for initial start-up. Clean the ap-
pliance and accessories.
7.1 Setting an operating mode
Your appliance is set to air extraction mode by default.
To use it in circulating-air mode, you must set the oper-
ating mode.
Note:For use in circulating-air mode, you require addi-
tional Accessories.
Requirement:The appliance is switched off.
1.
Press and hold and for approx.three seconds.
To set circulating-air mode (non-regenerable fil-
ter), press ⁠/ until LED2 lights up in the LED
display.
To set circulating-air mode (non-regenerable fil-
ter), press ⁠/ until LED3 lights up in the LED
display.
To convert the electronic control back to opera-
tion without the air recirculation filter, press ⁠/
until LED1 lights up on the LED display.
2.
To save the setting, press and hold and for ap-
prox. three seconds.
Or wait approx. 10seconds until the setting is
saved automatically.
To cancel the setting, press ⁠.
a A signal tone sounds as soon as the selected set-
ting is saved.
8  Basic operation
8.1 Switching on the appliance
Requirement:Align the remote control as precisely as
possible to the infrared receiver for the LED display.
Press to switch on the appliance.
a The appliance starts at fan setting2.
a The LED for the set fan setting lights up in the LED
display.
8.2 Switching off the appliance
Switch the appliance off when you are not using it.
Press to switch the appliance off.
a The appliance switches off. Any functions currently
in progress are cancelled.
8.3 Selecting a fan setting
Press or ⁠.
a The LED for the set fan setting lights up in the LED
display.
8.4 Switching on intensive mode
If particularly strong odours or vapours develop, you
can use intensive mode.
1.
so oft drücken, bis in der LED-Anzeige die LED4
für die Intensivstufe1leuchtet.
2.
so oft drücken, bis in der LED-Anzeige die LED5
für die Intensivstufe2leuchtet.
a After approx. 6 minutes, the appliance automatically
switches to fan setting 3.
8.5 Switching off intensive mode
To select a fan setting of your choice, press ⁠.
8.6 Switching on the fan run-on
Press ⁠.
a LED1 for the fan setting lights up in the LED dis-
play. LED6 flashes for the fan run-on.
a The appliance switches off automatically after ap-
prox. 10 minutes.
8.7 Switching off the fan run-on
Press ⁠.
a This immediately stops the fan run-on.
a The appliance switches to the fan setting that was
previously selected.
8.8 Switch on automatic mode
1
The optimum fan setting is set automatically using a
sensor.
Press ⁠.
a In the LED display, LED6 lights up for automatic
mode.
8.9 Switch off automatic mode
1
Press ⁠.
a The appliance switches to the fan setting that was
previously set.
a The ventilation is automatically ended when the
sensor detects no further change in the room air
quality.
a Automatic mode runs for a maximum of four hours.
8.10 Intermittent ventilation
With interval ventilation, the ventilation system switches
on and off in the selected setting for the selected time.
Note:This function is only available via a mobile device
with the HomeConnect app.
If the interval ventilation is switched on, LED6 continu-
ously flashes in the LED display for the interval ventila-
tion and the LED for the selected fan setting lights up.
1
Depending on the appliance specifications

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens LR97CAQ50 and is the answer not in the manual?

Siemens LR97CAQ50 Specifications

General IconGeneral
TypeCeiling built-in
Cord length1.3 m
CertificationCE, VDE
Product colorBlack, Silver
Built-in display-
Exhaust connection diameter150 mm
Noise level56 dB
Intensive speedYes
Number of speeds3
Type of extractionDucted/Recirculating
Noise level (low speed)41 dB
Maximum extraction power760 m³/h
Noise level (high speed)63 dB
Maximum recirculating power560 m³/h
Noise level (intensive speed)68 dB
Fluid dynamic efficiency classA
Grease filtering efficiency classE
Minimum distance from electric hob650 mm
Bulb typeLED
Bulb power3 W
Illuminance659 lx
Number of bulbs4 bulb(s)
Grease filter typeStainless steel
Motor power174 W
Connected load160 W
AC input voltage220 - 240 V
AC input frequency50 - 60 Hz
Annual energy consumption31.8 kWh
Weight and Dimensions IconWeight and Dimensions
Depth500 mm
Width900 mm
Height300 mm
Weight26900 g
Installation compartment depth487 mm
Installation compartment width888 mm
Installation compartment height299 mm