ICM MP CCQ ASP/ASC Page 5 of 37 Internal Use Only
• Nominal Voltage : 3.6V
• Nominal Capacity : 750 mAh
• GSM Capacity : 700 mAh
• Power Input : 1.8A (0.6 ms) / (4 ms)
• Cut-off Threshold : 3.2V
Stand-by Time
• Approx. 250 h / Li-Ion (measured at BSPAMFRMS = 9;
Number of neighboring cells = 0)
Talk Time
• Best case approx. 5 hours (lowest output level with
DTX
• Worst case approx. : 2.0 hours (highest output level with
DTX)
Condition for DTX : 40% user talk time
SIM Card
• Small (”Plug In”) 3V SIM card (Phase II)
•
To insert the SIM card, the battery pack must be
removed.
GSM Antenna
• A triple band PIFA antenna will be an integral part of the
mobile phone.
Receiver Sensitivity
• EGSM: -102 dBm (-104dBm-15.2) (Specification; static
& with fading)
•
PCN : -102 dBm (Specification; static & with fading)
The reception sensitivity must comply with the corresponding
GSM recommendations in all operating conditions
(temperature,
battery level ...).
•
EGSM: measurements according typical sensitivity are
not yet available.
•
PCN: measurements according typical sensitivity are
not yet available
Measurement values are referred to the external antenna
connector.
Transmitter Power • EGSM: nominal 2W (Specification: Class 4 Mobile
phone)
•
PCN: nominal 1W (Specification: Class 1 Mobile phone)
Transmitter output characteristics is according to GSM 11.10
specification implying all specified operating conditions
(temperature, battery level ...).