Chapter 2
Installing the Device
RUGGEDCOM RST2228
Installation Guide
16 Connecting Low DC Power
IMPORTANT!
When connecting the device to a DC power source, make sure the source provides only positive voltage.
1. Connect the power supply terminal block to the device.
1
2
Figure13:Assembling the Power Supply Terminal Block
1.Pluggable Terminal Block 2.Screw-Type Terminal Block
2. Connect the positive wire from the power source to the positive terminal on the terminal block.
1
2
3
4
5
3
4
5
7
8
6
6
7
8
Figure14:DC Terminal Block Wiring
1.Pluggable Terminal Block 2.Screw-Type Terminal Block 3.Positive (+) Terminal for PS1 4.Chassis/Ground Terminal for PS1
5.Negative (-) Terminal for PS1 6.Positive (+) Terminal for PS2 7.Chassis/Ground Terminal for PS2 8.Negative (-) Terminal for
PS2
3. Connect the negative wire from the power source to the negative terminal on the terminal block.
4. For pluggable terminal blocks, install the safety cover.

Related product manuals