Description
3.2 LED displays
SCALANCE W788-xPRO/RR / W74x-1PRO/RR
14 Operating Instructions, 07/2014, A5E02280448-08
R2 Yellow
W788-xPRO/RR in access point mode:
Data transfer over the second WLAN port.
W788-xPRO/RR in client mode or W74x-1PRO/RR:
The LED is always off because the 2nd interface is not available in client
Green
W788-xPRO/RR in access point mode:
The WLAN interface is initialized and ready for operation.
W788-xPRO/RR in client mode or W74x-1PRO/RR:
The LED is always off because the 2nd interface is not available in client
Flashing green
W788-xPRO/RR in access point mode:
The channels are being scanned.
W788-xPRO/RR in client mode or W74x-1PRO/RR:
The LED is always off because the 2nd interface is not available in client
Green flashing
quickly
W788-xPRO/RR in access point mode:
With 802.11h, the channel is scanned for one minute for primary users
before the channel can be used for data traffic.
W788-xPRO/RR in client mode or W74x-1PRO/RR:
The LED is always off because the 2nd interface is not available in client
PRESET function completed successfully.
Power supply over the M12 connector (X2).
F Red An error has occurred during operation of the SCALANCE W788-
Flashing red,
R1 or R2
flashing green at
A primary user was found on all enabled channels.
Note
Primary user (radar) on all enabled channels
If the device detects a primary user on all enabled channels (for example radio waves of a
radar station), the LEDs F
and
flash. No data traffic is then possible for the next 30
minutes. After this time, the device runs the scan again and checks whether a primary user
still exists. If no primary user is detected, data traffic is possible again.
The wait time of 30 minutes is
necessary due to legal requirements and cannot be shortened