Configuring with Web Based Management 
  6.6 "Interfaces" menu 
SCALANCE W780/W740 to IEEE 802.11n Web Based Management 
Configuration Manual, 08/2018, C79000-G8976-C267-13 
309 
●  CL M-Signal [dBm] 
If the client has an iPCF-MC connection, the user signal of the management channel is 
displayed. 
●  Roaming Counter 
The roaming counter shows how often the client has changed access points during the 
recording. After 4 294 967 295 changes the counter is reset. 
●  Operative Channel 
The current channel or the channel on which the client is connected to the access point 
●  AP System Name 
The system name of the access point 
●  BSSID 
The BSSID (Basic Service Set Identification) of the access point. 
●  Connected Stations 
Number of clients connected to the access point. 
●  Bidirectional Status 
Shows whether the data of the access point are also being recorded. 
The table below the graphic contains the following columns: 
● 
 
Shows the WLAN interface to which the information applies. Since a client has a WLAN 
interface, there is only ever one row for "WLAN 1" in this table. 
● 
 
Specify the time interval between acquiring two measured values in milliseconds. The 
first measured value is displayed only after the set time interval has elapsed. 
● 
 
Specify how many measurements should be made. 
● 
 
If you enable the option check mark, the number of measurements is unlimited The 
"Samples" box is grayed out . The signal recorder runs until it is stopped manually or the 
device is reconfigured. 
You can only select this option starting at a time interval ≥ 100 milliseconds. 
If the recording contains more than 10000 measurements, the last 10000 measurements 
are listed in the csv file and the PDF file. 
● 
 
If you enable the setting the values of the access point as of a time interval of ≥ 10 
milliseconds. 
The setting is supported by access points with the following versions: SCALANCE W700 