Configuring with Web Based Management   
6.10 "iFeatures" menu 
  SCALANCE W780/W740 to IEEE 802.11n Web Based Management 
410  Configuration Manual, 08/2018, C79000-G8976-C267-13 
In access point mode, the table has the following additional columns: 
● 
 
Specify which protocol is handled with priority by the WLAN interface. 
–  PROFINET 
if you set PROFINET, there must be no PROFINET controller downstream from the 
client. 
–  EtherNet/IP 
If you set Ethernet/IP, there must be no scanner downstream from the client. 
–  Disabled 
The function is disabled. 
● 
 
Specify the cycle time.  
The following points need to be taken into account when setting the cycle time. Otherwise 
it may not be possible to establish stable communication. 
–  The range of values is 16 - 512. The set value should correspond the cycle time of 
PROFINET or EtherNet/IP. 
–  There is only one access point in the system; in other words, the clients move only in 
one wireless cell. In this case, update times >= 16 ms are supported. 
–  There are several access points in the system that communicate over different 
channels. The clients roam between the access points. In this case, select update 
times >= 32 ms. 
In addition to the guide values shown above, remember that the shortest cycle time to be 
set is calculated according to the formula "4 ms * max. number of nodes". 
● 
 
The selected setting affects the scanning of the logged-on clients.  
The following settings are available: 
–  All Channels 
The client scans all permitted channels and selects the access point with the best 
signal strength and connects to it. 
–  Next Channel 
The client scans the next channel from its permitted channel list. If an access point is 
there, it connects to it. If it does not find an access point on this channel, it scans the 
next channel.