Certifications and approvals
6.1 Notes on the CE Mark
SCALANCE X-200
94 Compact Operating Instructions, 12/2010, A5E00813159-11
Device type
SCALANCE
IEC 60068-2-6 vibration IEC 60068-2-27 shock
X201-3P IRT 5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X200-4P IRT 5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
Note
The interfaces of the X-200 IE switches can be divided into groups each with 4 ports:
P1 to P4
P5 to P8
P9 to P12
etc.
If only ports of different port groups are used, the device meets the requirements for
Environment B in compliance with IEEE 802.3, Section 33.4.1.1. If ports of the same port
group are used, the requirements for Environment A are met.