Programming via OPC UA
10.2 OPC UA variables
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
130 Operating Instructions, 04/2020, C79000-G8976-C512-03
Table 10- 17 Antenna
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/LastAccess/Rfid/Antenna
R
Diagnostics on the last transponder access
Indicates the antenna via which the transponder was accessed
with the last command.
The prerequisite is that the "Parallel" or "Diagnostics" option is
Two-digit number
The first digit stands for the read point index, the second digit for
the antenna index within the read point.
Example:
• Read point 1, antenna 1: 11
• Read point 2, antenna 1: 21
Table 10- 18 CurrentPowerLevel
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/LastAccess/Rfid/CurrentPowerLevel
Diagnostics on the last transponder access
Outputs the power with which the last command was executed
on the transponder. This variable is only supported by UHF
readers.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Decimal number for the power in [dB]
Increment: 0.25 dB
• 0
• 5.00 ... 33.00