Technical data
13.2 Technical specifications for RF186CI, RF188CI
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
182 Operating Instructions, 04/2020, C79000-G8976-C512-03
2)
• Rated value • 24 VDC
• Permitted range • 20 to 30 VDC
Current consumption without reader Typ. 130 mA
Current draw via reader interfaces
max. 800 mA each, at 24 V DC
Current consumption via I/O interfaces
• Class A • max. 150 mA each, at 24 V DC
• Class B • max. 500 mA each, at 24 V DC
• During operation
-25 ... +55 °C
• During transportation and storage
-40 ... +70 °C
Oscillation, vibration in operation
(according to IEC 60068-2-27)
0.75 mm (10 … 58 Hz)
Shock resistance, shock in operation
(according to IEC 60068-2-6)
30 g
Approvals
• CE
• cULus (file E85972)
• FCC Code of Federal Regulations,
CFR 47, Part 15,
Sections 15.107 and 15.109 (Class A)
• PNO-certified according to Conformance
Class B
Depending on the connected reader.
All supply and signal voltages must be safety extra low voltage (SELV/PELV according to
IEC 61140) 24 V DC supply: Safety (electrical) isolation of low voltage (SELV/PELV acc. to