EasyManua.ls Logo

Siemens SIMEAS-T 7KG6111-2LK11-0B User Manual

Siemens SIMEAS-T 7KG6111-2LK11-0B
20 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
Operating Instructions
Transducer without auxiliary power
for alternating current
for alternating voltage
for alternating voltage with expanded end range
7KG6111 and 7KG6101
Compact device for DIN rail mounting
Operating Instructions
A5E38679986C / RS-AB
Operating
Instructions
SIMEAS-T
s
Question and Answer IconNeed help?

Do you have a question about the Siemens SIMEAS-T 7KG6111-2LK11-0B and is the answer not in the manual?

Siemens SIMEAS-T 7KG6111-2LK11-0B Specifications

General IconGeneral
BrandSiemens
ModelSIMEAS-T 7KG6111-2LK11-0B
CategoryTransducer
LanguageEnglish

Summary

Safety instructions

QUALIFIED PERSONNEL

Defines qualifications required for safe installation, operation, and maintenance of the device.

Operating Instructions

Area of application

Describes transducer use in power supply and distribution for signal transmission over distances.

Characteristic curves

Illustrates output signal vs. input signal for AC current and voltage transducer types.

Performance characteristics

Lists key features like precision, reliability, EMC immunity, quality, and small dimensions.

Operating principle

Explains the transformer, rectification, filtering, evaluation, and amplifier stages of the transducer.

Overview circuit diagram

Shows a block diagram of the transducer's internal components and signal flow.

Technical specifications

Details electrical and environmental parameters, input/output ranges, and performance data.

Rating plate symbols

Explains common symbols found on the product's rating plate.

Description

Describes the transducer's physical characteristics, mounting, and material properties.

Ordering data

Ordering data for alternating voltage (G) MUU

Provides codes and options for configuring and ordering the alternating voltage transducer.

Ordering data for alternating current (G) MUI

Provides codes and options for configuring and ordering the alternating current transducer.

Mounting and operation

Installation

Details location requirements, temperature, enclosure type, terminals, and DIN rail mounting.

Connection

Explains high voltage regulations, receiver connection, load limits, pin assignment, and testing.

Installation material

Specifies cable requirements for measuring circuits based on isolation levels.

Commissioning

Maintenance

Calibrating and testing

Calibration of the voltage transducer

Explains start and full-scale value calibration steps for standard and expanded range voltage transducers.

Calibration of the current transducer

Details the full-scale value calibration procedure for current transducers.

Related product manuals