NCK alarms
11/2006 Overview of Alarms
2-41
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
4050 NC code identifier %1 cannot be reconfigured to %2
Parameters: %1 = String: Old identifier
%2 = String: New identifier
Definitions: Renaming of an NC code was not possible for one of the following reasons:
- The old identifier does not exist
- The new identifier is within another type range.
NC codes/keywords can be reconfigured as long as you stay within the type range.
Type 1: "true" G codes: G02, G17, G33, G64, ...
Type 2: named G codes: ASPLINE, BRISK, TRANS, ...
Type 3: addresses which can be set: X, Y, A1, A2, I, J, K, ALF, MEAS, ...
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Correct machine data 10712:
NC_USER_CODE_CONF_NAME_TAB (protection level 1).
The list must be built up as follows:
Even address: Identifier to be modified Following odd address: New identifier
e.g.: NC_USER_CODE_CONF_NAME_TAB [10] = "ROT", NC_USER_CODE_CONF_NAME_TAB
[11] = " " clears the ROT function from the control
Program
Continuation:
Switch control OFF - ON.
4060 Standard machine data loaded (%1, %2)
Parameters: %1 = Identifier 1
%2 = Identifier 2
Definitions: The standard MD were loaded because
- a cold start was requested or
- the MD buffer voltage failed or
- an initialization was requested for loading the standard machine data (MD 11200 INIT_MD).
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department. After automatically loading the standard
MDs, the individual MDs must be entered or loaded in the relevant system.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
4062 Backup data loaded
Definitions: The user data saved in the flash memory are loaded to the SRAM.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department. Load specific machine data again.
Program
Continuation:
Clear alarm with the RESET key. Restart part program

Other manuals for Siemens Simodrive 611

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simodrive 611 and is the answer not in the manual?

Siemens Simodrive 611 Specifications

General IconGeneral
BrandSiemens
ModelSimodrive 611
CategoryMedia Converter
LanguageEnglish

Related product manuals