Overview of System Error Alarms
1
Overview of Alarms
2
List of Action Numbers
3
Error Codes of Alarm 300500
4
System Reactions on Alarms
5
Appendix
A

Other manuals for Siemens Simodrive 611

Question and Answer IconNeed help?

Do you have a question about the Siemens Simodrive 611 and is the answer not in the manual?

Siemens Simodrive 611 Specifications

General IconGeneral
BrandSiemens
ModelSimodrive 611
CategoryMedia Converter
LanguageEnglish

Summary

Overview of System Error Alarms

System error

The following alarms are system errors... If such a system error occurs, please contact the hotline...

Overview of Alarms

NCK ALARMS

NCK alarms are sorted by ascending alarm number in each section. There are gaps in the sequence.

HMI ALARMS

HMI alarms are sorted by ascending alarm number in each section. There are gaps in the sequence.

SIMODRIVE ALARMS

SIMODRIVE alarms are sorted by ascending alarm number in each section. There are gaps in the sequence.

PLC ALARMS

PLC alarms are sorted by ascending alarm number in each section. There are gaps in the sequence.

List of Action Numbers

No. 1

Run Init phase (tasks are initialized after power on).

No. 2

Perform reset (VDI signal: Reset, mode group reset or after power on).

No. 3

Activate Reset Init blocks (VDI signal: Reset).

No. 4

Perform reset, end of program has been detected (NC block with M30).

No. 5

Change the mode to the MDI or AUTOMATIC program operating mode (VDI signal: Mode group).

No. 6

Automatic change from an internal mode to the mode set externally (with TEACH_IN).

No. 7

Change the mode to a manual mode (VDI signal (mode group): JOG, TEACH_IN, REF).

No. 8

Activate test run (VDI signal: Rapid traverse override).

No. 9

Deactivate test run (VDI signal: Rapid traverse override).

No. 10

Start program processing (VDI signal: NC Start).

No. 11

Start continuation of interpreter processing (internal preprocessing stop).

No. 12

Start continuation of the selected process (JOG, reference point or digitizing).

Error Codes of Alarm 300500

Error code 0001 H

Error in P:-RAM. Incorrect address. Detected written bitmap read error during power-up.

Error code 0002 H

Error in X: or Y:-RAM. Incorrect address. Detected written bitmap read error during power-up.

Error code 0003 H

Computing time overrun. Drive processor computing time insufficient for selected functions.

Error code 0004 H

Servo sign-of-life monitoring not updated. Sign-of-life of the servo is monitored.

Error code 0005 H

Error in state switch cabinet. Cause is probably a hardware error on the control module.

Error code 0006 H

Background loop exited. Cause is probably a hardware error on the control module.

Error code 0007 H

Synchronization failed. Illegal state read by hardware during cycle synchronization.

Error code 0010 H

Stack overrun. Limits of internal processor or software stack violated.

Error code 0011 H

NMI due to watchdog. Watchdog on control module timed out.

Error code 0012 H

NMI due to clock cycle failure. NC basic cycle failed.

Error code 0013 H

Clock cycle came too early. NC basic cycle pulse does not match clock timing.

Error code 0014 H

Illegal Opcode, Trace, SWI, NMI (DSP). Processor detected illegal command in program memory.

Error code 0015 H

Error in checksum test. Difference detected between setpoint and actual checksums.

Error code 0016 H

SSI interrupt. Illegal processor interrupt occurred.

Error code 0017 H

SCI interrupt. Illegal processor interrupt occurred.

System Reactions on Alarms

Names COMPBLOCKWITHREORG

Block preparation error, rectifiable by program modification. Reorganization after modification.

Names COMPENSATIONBLOCK

Block preparation error, rectifiable by program modification.

Names INTERPRETER STOP

Program execution aborted after prepared blocks (interpolator buffer) are processed.

Names TECHNICAL SUPPORT

Questions? Contact Hotline: Europe and Africa time zone: A&D Technical Support.

Names SHOWALARMAUTO

Alarm displayed when machine data ENABLE_ALARM_MASK bit 0 is set.

Names SHOWWARNING

Alarm displayed when machine data ENABLE_ALARM_MASK bit 1 is set.

Names ALLBAGSNOREADY

Ready canceled in all mode groups. NCK REACTIONVIEW|NOREADY applied.

Names DELAYALARMREACTION

Alarm reactions buffered channel-specifically and not active.

Names NODELAYALARMREACTION

The DELAY_ALARM_REACTION state is canceled.

Appendix

A.1 Abbreviations

Lists common abbreviations used in the document.