5-869
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
System Reactions on Alarms 5
Names COMPBLOCKWITHREORG
Effect Block preparation has detected an error, which can be rectified by modifying the pro-
gram. Reorganization is performed after a program modification.
− Correction block with reorganization.
Names COMPENSATIONBLOCK
Effect Block preparation has detected an error, which can be rectified by modifying the pro-
gram.
− Correction block
Names FOLLOWUP
Effect Follow-up of axes
− NC switches to follow-up mode
Names INTERPRETER STOP
Effect Program execution is aborted after all the prepared blocks (interpolator buffer) have
been processed.
− Interpreter stop
Names LOCALREACTION
Effect − Local alarm response
Names NOALARMREACTION
Effect − No alarm reaction