Installation
Explosion-protected machines
56100000002002, 01/2016
103
5.2 Installation
5.2.1 Installation of explosion-proof machines
Only use explosion-protected machines in appropriate areas in accordance with
directive 1999/92/EG .
If the certification is supplemented by an X, please note the special conditions in
the EC type test certificate.Special conditions for explosion-proof machines
(Page 82)
When installing electrical systems in hazardous zones, observe EN / IEC 60079-
14 and the corresponding country regulations.
The machine temperature class specified on the rating plate must be equal to or
greater than the temperature class of any combustible gases that may develop.
At the completely installed drive system, investigate the influence of heat and cold
sources on mounted components according to EN 60079-14.
Recommended maximum interface temperatures for flange-mounted motors:
Type of protection
Ex e, Ex nA
Supply voltage
Line supply
Control range
-
Cooling method
Self-cooled
Frame size
63 ... 200
Mechanical design
EN 50347
Ambient temperature
-20 °C ... +40 °C
Temperature class
T3
No. of poles
2
4
Max. shaft temperature
60 °C
75 °C
Max. flange temperature
60 °C
75 °C
Select mounted equipment such as brakes, external fans or incremental encoders
according to the requirements of Directive 94/9/EC up to April 19, 2016 or from
April 20, 2016, Directive 2014/34/EU.