Maintenance
9.3 Corrective maintenance
1MB..1/2/3/4 - shaft heights 63 ... 355
130 Operating Instructions, 06/2020, A5E44455710A
9.3.13 O-ring seal
If O-ring seals are present, you should check that they are in perfect condition and that the
O-ring seals are properly seated in the grooves between the components. Replace damaged
O-ring seals.
O-ring seals can be present on the following components, for instance:
Adapters, tapers
Entries, glands
Bearing seals
End shield seals
Terminal box sealing
etc.