EasyManuals Logo

Siemens Sinumerik 840D Series User Manual

Siemens Sinumerik 840D Series
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #28 background imageLoading...
Page #28 background image
1 Alarms 11.02
1-28
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
4010 Invalid identifier used in machine data %1[%2]
Parameters: %1 = String: MD identifier
%2 = Index: MD array index
Definitions: When determining a name in the NCK tables (arrays) for: machine axes, Euler angles,
direction vectors, interpolation parameters and intermediate point coordinates, one of the
following syntax rules for the identifier to be entered has been violated:
The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly
with a numerical extension (840D: 1-99, FM-NC: 1-9)
The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for sys-
tem variable).
The identifier must not be a keyword of the NC language (e.g. POSA).
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Enter the identifier for user-
defined names with correct syntax in the displayed MD.
Machine axes: AXCONF_MACHAX_NAME_TAB
Euler angles: EULER_ANGLE_NAME_TAB
Normal vectors: NORMAL_VECTOR_NAME_TAB
Direction vectors: 10640 DIR_VECTOR_NAME_TAB
Interpolation parameters: 10650 IPO_PARAM_NAME_TAB
Intermediate point coordinates: 10660 INTERMEDIATE_POINT_NAME_TAB
Program Continuation: Switch control OFF - ON.
4011 Channel %1 invalid identifier used in machine data %2[%3]
Parameters: %1 = Channel number
%2 = String: MD identifier
%3 = Index: MD array index
Definitions: When defining names in the channel-specific tables for geometry axes and channel axes,
one of the following syntax rules for the identifier to be entered has been violated:
The identifier must be an NC address letter (A, B, C, I, J, K, U, V, W, X, Y, Z), possibly
with a numerical extension (840D: 1-99, FM-NC: 1-9).
The identifier must begin with 2 arbitrary capital letters but not with $ (reserved for sys-
tem variable).
The identifier must not be a keyword of the NC language (e.g. POSA).
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Enter the identifier for user-
defined names with correct syntax in the displayed MD
Geometry axes: 20060 AXCONF_GEOAX_NAME_TAB
Channel axes: 10000 AXCONF_MACHAX_NAME_TAB
Program Continuation: Switch control OFF - ON.

Other manuals for Siemens Sinumerik 840D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinumerik 840D Series and is the answer not in the manual?

Siemens Sinumerik 840D Series Specifications

General IconGeneral
AxesUp to 31 axes
Power Supply24 V DC
Control TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
PLCIntegrated PLC (programmable logic controller)
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
Max. Number of ChannelsUp to 10 channels

Related product manuals