A5E33329501 SITRANS LUT400 (HART) – OPERATING INSTRUCTIONS Page 251
mmmmm
Technical Data
Alarm Relay
1 Form C (SPDT), NO or NC relay
Rated 1A at 250 V AC, non-inductive
Rated 3A at 30 V DC
Inputs
Discrete (2)
0-50 V DC maximum switching level
Logical 0 = < 10 V DC
Logical 1 = 10 to 50 V DC
3 mA maximum draw
Programming
Primary
Local push buttons
Secondary
PC running SIMATIC PDM
PC running Emerson AMS Device Manager
PC running a web browser
PC running a Field Device Tool (FDT)
Field Communicator 375/475 (FC375/FC475)
Compatible Transducers
EchoMax series and STH series
Transducer Frequency
10 to 52 kHz
Communication
•HART 7.0
•USB
Display
•Back-lit LCD
Dimensions:
60 x 40 mm (2.36 x 1.57")
Resolution:
240 x 160 pixels
Removable display, operational up to 5 m from enclosure base