www.sigineer.com
21
23 AC Output Mode
Split phase
28 RS485
Communication Address
Default 001. 001-255
Settable. For external
solar charger expansion.
36 Lithium BMS Protocol
Default L01
37 Real time setting---Year
38 Real time setting---Month
39 Real time setting---Date
40 Real time setting---Hour
41 Real time setting---Minute
42 Real time setting---Second
43 Battery Equalization
Disabled (Default)
43 Battery Equalization
Enable
44 Battery Equalization
Voltage
Default 58.4V, 48~60V
settable
45 Battery Equalization Time
Setting range is from
5min to 900min.
Increment of each click
is 1min.
46 Battery Equalization
Timeout
Setting range is from
5min to 900min.
Increment of each click
is 1 min.
47 Equalization Interval
Setting range is from 1 to
90 days. Increment of
each click is 1 day.
48 Equalization Activated
Immediately
Disabled (Default)
48 Equalization Activated
Immediately
Enable