www.sigineer.com
52
Transfer Time
10 ms(Typical) ; 20 ms Max; <30ms
Parallel
10 ms(Typical) ; 20 ms Max; <30ms
Parallel
AC Input Breaker
40A
40A
Inverter Mode
Battery Voltage
48 VDC
48 VDC
Output Waveform
Pure Sine Wave
Pure Sine Wave
AC Voltage Regulation (Batt. Mode)
120 VAC ± 5%
230 VAC ± 5%
Surge AC Output Power
6000W (5 secs)
10000W (5 secs)
Output Frequency
50Hz/60Hz(default)
50Hz/60Hz(default)
Max. Output Fault Current/ Duration
80A/ 300μs
80A/ 300μs
Max. Output Overcurrent Protection
76A
65A
DC To AC Efficiency (Peak)
90%
93%
Overload Protection
5s@≥150% load; 10s@110%~150% load
5s@≥150% load; 10s@110%~150% load
Cold Start Battery Voltage* (Without
PV or AC)
46.0Vdc/Li Mode(Default 30%, Low DC
Cut-off SOC +10%)
46.0Vdc/Li Mode(Default 30%, Low DC
Cut-off SOC +10%)
Minimal Battery Voltage To Activate
AC Charger(Without PV)
40.8Vdc
40.8Vdc
Low DC Warning Voltage (Lead-Acid
Mode)
44.0Vdc @ load < 20%
44.0Vdc @ load < 20%
42.8Vdc @ 20% ≤ load < 50%
42.8Vdc @ 20% ≤ load < 50%
40.4Vdc @ load ≥ 50%
40.4Vdc @ load ≥ 50%
Low DC Warning Return
Voltage(Lead-Acid Mode)
46.0Vdc @ load < 20%
46.0Vdc @ load < 20%
44.8Vdc @ 20% ≤ load < 50%
44.8Vdc @ 20% ≤ load < 50%
42.4Vdc @ load ≥ 50%
42.4Vdc @ load ≥ 50%
Low DC Cut-off Voltage (Lead-Acid
Mode)
42.0Vdc @ load < 20%
42.0Vdc @ load < 20%
40.8Vdc @ 20% ≤ load < 50%
40.8Vdc @ 20% ≤ load < 50%
38.4Vdc @ load ≥ 50%
38.4Vdc @ load ≥ 50%
Low DC Cut-off Voltage (Li Mode)
42.0Vdc
42.0Vdc
Low DC Warning SOC (Li Mode)
Low DC Cut-off SOC +5%
Low DC Cut-off SOC +5%
Low DC Warning Return SOC (Li
Mode)
Low DC Cut-off SOC +10%
Low DC Cut-off SOC +10%
Low DC Cut-off SOC (Li Mode)
Default 20%, 5%~50% settable
Default 20%, 5%~50% settable
High DC Recovery Voltage
56.4Vdc(C.V. charging voltage)
56.4Vdc(C.V. charging voltage)
High DC Cut-off Voltage
60.8Vdc
60.8Vdc
Idle Power
60W
60W
Charge Mode
CV & Float Charge voltage
48.0V~58.4V Settable
48.0V~58.4V Settable
Maximum PV Array Power
4000W
6000W
Max PV Input Current
22A
22A
MPPT Efficiency
98.0% max.
98.0% max.
PV Open Circuit Voltage
250Vdc
450Vdc
PV Charger Start-up Voltage
150Vdc±10Vdc
150Vdc±10Vdc
MPPT Range @ Operating Voltage
120-250VDC
120-430VDC
Overcharge Protection
60Vdc
60Vdc
Maximum Solar Charge Current
80 A
100 A
Maximum AC Charge Current
40 A
80 A
Maximum Charge Current(PV+AC)
80A
100 A
Battery Voltage Accuracy
+/-0.3%
+/-0.3%