EasyManuals Logo

Signal Hound VSG60A User Manual

Default Icon
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #10 background imageLoading...
Page #10 background image
VSG60A Preliminary Specifications | Timebase
7
6 VSG60A Preliminary Specifications
Unless otherwise noted, the specifications listed are under default conditions, digital tuning enabled.
Frequency
Specified Range
All Modes
50 MHz to 6 GHz
Useable Range (typical)
All Modes
30 MHz to 6 GHz
Resolution
Digital Tuning Disabled
1/6 Hz
Digital Tuning Enabled
< 1 µHz
LO Switch Time
Queued Hops
200 µs
Software-controlled
80 ms typical
Accuracy
Internal timebase, Aging
+/- 1 ppm/yr
Initial accuracy
+/- 1 ppm
I/Q Symbol Clock Range
All Modes
12.5 kHz to 51.2 MHz
I/Q Symbol Clock Accuracy
All Modes
+/- 1 ppm + timebase
accuracy
Commonly used symbol rates
0 ppm + timebase accuracy
I/Q Symbol Clock Switch Time
All modes
100 ms typical

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Signal Hound VSG60A and is the answer not in the manual?

Signal Hound VSG60A Specifications

General IconGeneral
BrandSignal Hound
ModelVSG60A
CategoryPortable Generator
LanguageEnglish