Accuracy | ±0.1 °C |
---|---|
Resolution | 0.01 °C |
Power Supply | 115 / 230 V AC, 50 / 60 Hz |
Dimensions | 153 x 330 x 260 mm |
Weight | 5.5 kg |
Display | LCD |
Stability | ±0.05 °C |
Cooling Time | 40 min (from 165 to 20 °C) |
Measurement Range | -20 to 165 °C |
Explains hazard signs and symbols used in the manual for user safety and understanding.
Details the process of receiving, unpacking, and checking the delivered calibrator and its accessories.
Specifies the correct applications and limitations for the TP17 / TPM calibrator series.
Outlines the terms and conditions of the manufacturer's warranty for the calibrator.
Clarifies the manufacturer's liability regarding improper installation, use, or non-compliance with instructions.
Defines the necessary qualifications and awareness required for personnel operating the calibrator.
Provides general safety guidelines, national regulations, and environmental condition requirements.
Details specific safety precautions related to thermal fuses and hazardous gases.
Covers safety precautions for handling and using various calibration liquids like water and silicone oil.
Describes the physical components and design of the TP17 / TPM calibrator, including its housing and parts.
Explains the different operational modes and measuring inserts supported by the calibrator.
Details the serial RS485 communication interface and its use with PCs and networks.
Specifies the required installation site, operating position, and environmental conditions for safe use.
Provides instructions and safety warnings for connecting the calibrator to the power supply.
Outlines the steps for preparing the calibrator, including selecting and inserting measuring inserts.
Details the use of adapter sleeves for dry block calibration of temperature sensors.
Explains the use of a special infrared insert for calibrating infrared thermometers.
Describes the surface insert for calibrating surface temperature sensors and measurement considerations.
Covers the setup and components for micro bath calibration, including safety and accessories.
Provides step-by-step instructions for safely powering the calibrator on, cooling it down, and switching it off.
Introduces the three main operating modes available: Calibration, Set point, and Main menu.
Details the controller's displays, buttons, and LED indicators for operating the calibrator.
Explains the primary operating mode for performing calibrations and interpreting the display.
Describes how the reference and set temperatures are shown on the controller's displays.
Explains the LED indicators and PID algorithm used for temperature control status.
Details how LED OUT 2 indicates the status of the fan or cooling system.
Shows how to view the heating/cooling capacity and total operating hours of the calibrator.
Guides on how to temporarily modify a saved set temperature using the set point mode.
Describes how to access and navigate the main menu for calibrator settings and functions.
Explains how to switch automatic temperature control on and off for specific tasks.
Details how to manually adjust the heating/cooling output capacity of the calibrator.
Guides on saving and retrieving fixed set temperatures for the 'S' version calibrators.
Explains how to create custom temperature profiles using heating/cooling gradients and duration times.
Describes the requirements and procedures for testing temperature sensors using the calibrator.
Outlines the steps before, during, and after the actual testing process for calibrating specimens.
Provides instructions and safety requirements for returning a defective calibrator to the manufacturer for repair.
Covers essential maintenance checks, replacement of wear parts like the magnetic stirrer.
Explains the process and recommendation for annual recalibration to maintain accuracy.
Details procedures for cleaning the external housing, vent grilles, and measuring inserts.
Provides safety instructions and guidelines for safely transporting the calibrator.
Instructs on the proper disposal procedures for used calibration liquids according to safety data sheets.
Outlines the correct methods for disposing of the calibrator unit, emphasizing not to use household waste.
Lists common technical specifications applicable to all TP17 / TPM series calibrators.
Provides detailed technical specifications for the TP 17 series calibrators.
Lists specific technical data for the TP 17 ... S series calibrators, including serial interface.
Details the technical specifications for the TP M ... S series calibrators, covering various functions.
Presents graphical data on the heating and cooling times for different calibrator models and functions.