Temperature calibrators
Series TP17 / TPM
Operating manual
(Translation)
Operating manual
.................................................... page 1 - 60

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the SIKA TPM 165 S-U and is the answer not in the manual?

SIKA TPM 165 S-U Specifications

General IconGeneral
Stability±0.05°C
Resolution0.01°C
Block Depth150 mm
Protection ClassIP20
Power Supply50/60 Hz
Operating Temperature5°C to 40°C
Heating TimeApprox. 15 min to 165°C from ambient

Summary

Device description

Intended use

CAUTION! Risk of burns!

Warns about the danger of touching hot parts of the calibrator during operation.

CAUTION! Material damage!

Alerts users to potential damage caused by incorrect use of measuring inserts or heat transfer media.

Safety Instructions

General safety instructions

Lists general safety regulations and best practices for working with the calibrator.

Special safety instructions

Safety instructions for the application of calibration liquids

Construction and function

Functions

Commissioning and operation

Electrical connection

Preparation of the calibrator

Dry block calibrator

Calibrator for infrared thermometer

Calibrator for surface temperature sensors

Micro bath calibrator

Notes on the calibration liquid

Information on filling amounts

Filling the micro bath

Switching on, cool down and switching off

Operating modes

Operation

Control elements of the controller (controller type K32SK)

Details the functions of the controller's displays, buttons, and LEDs.

Calibration (calibration mode)

Display of reference and set temperature

Explains how reference and set temperatures are displayed on the controller.

Display of temperature control

Describes how the LED OUT 1 indicates the active temperature control status.

Display of fan/ cooling control

Set a temporary set temperature (set point mode)

Main menu

Automatic control

Manual control

Set point memory (S version)

Gradient control / temperature profile (S version)

Setting values for „SLor“ and „SLoF"

Provides tables of heating and cooling gradient values for different calibrator types.

Setting the heating gradient (S version)

Setting the cooling gradient (S version)

Setting the duration time (S version)

Testing process / Calibration

Testing temperature sensors

Explains the process of testing temperature sensors using the calibrator.

CAUTION! Incorrect results!

Warns about potential incorrect calibration results with earthed thermal elements.

Testing process

Performing testing process

Describes the actual steps during a calibration test.

Problems

Troubleshooting Common Issues

Addresses common issues like sensor interruption, fan errors, and display problems.

Return shipment to the manufacturer

WARNING! Risk of injury due to insufficient cleaning!

Highlights the dangers of returning a dirty or contaminated device.

Maintenance, cleaning and transport

Maintenance

Details maintenance checks, recalibration, and component care.

Recalibration

Cleaning

Transport

Decommissioning and disposal

Technical data

Characteristics series TP 17 ...

Characteristics TP 17 ... S

Characteristics series TP M ... S

Related product manuals